When should I replace my UPS batteries?

You must replace your UPS batteries when they no longer support connected equipment.

You should replace your UPS batteries once they have reached a certain age or a clear reduction in availble run-time is evident.

Depending on the model of your UPS it may or may not conduct regular checks on the battery capacity.  If it doesn't, how will you ever know whether the batteries have the capacity to support the connected equipment for the required time.  If it does, how long does it test for and does it give a good indication of capacity.

Some UPS units test their batteries for 10 seconds every 2 weeks, and about all that proves is that the batteries are sufficient to operate for 10 seconds, not particularly helpful if your PC takes 30 seconds to shut down.

Replacing a UPS battery based on age

If you've already spent money on a UPS, its a fair bet that you consider losing power to your PC is too great a risk.  Why would you then risk losing power to your PC by using a battery right up until the end of its life.  For this reason we say a system under ideal conditions should have the batteries replaced every 4 years, and a system in fairly ordinary conditions with high temperatures and lots of discharges every 3 years.

Replacing a UPS battery based on performance

From new the UPS battery is losing capacity, it starts slowly at first then gradually picks up the pace until it gets down to 80% then after that it drops off very rapidly.  The best way to determine your battery capacity is to perform a known-load test.  Rather than relying on the internal battery test, choose a time that suits you and turn off the power to the UPS.

If you have software or the UPS has a display you can keep an eye on the battery capacity / run-time available, if not most UPS will beep differently once they have reached a pre-defined 'almost flat' setting.  Take note of the time taken to reach a certain point then turn the power back on and let the UPS recharge.  Conduct this test every 6 months or so, and as soon as you notice the run-time shorten significantly it is time to replace the batteries.

 

Facebook Twitter Digg Delicious Stumbleupon Google Bookmarks 

Search

Shopping Cart

The shopping cart is empty

Pricing Discounts

Free Shipping for Battery Kits over $300 to Metro areas.
Government orders accepted

read more

Poll

How did you find our site?
 

Contact Us

Email: sales@apcrbc.com.au

 

Phone: 1300 799 161

Onsite Service

Need someone to replace the batteries or install new equipment, we can help with service providers in every capital city

read more

Short Battery Life?

We can perform a calibration on your UPS battery charger to extend the life of your UPS batteries

read more

 

Looking for other APC Products?

As an APC Select Partner we have access to the full range of APC products at very competitive prices.

 

read more